MPT Forward Pattern Full Manual Valve Body Features
- 2nd Gear Lockup (locks torque converter as soon as second gear is manually shifted, lockup switch must be on)
- Locked 4-3 Downshift
- No use of governor pressure solenoids/ transducers (Much more consistent shifts on high pressure valve bodies)
- Valve Body Pressure adjustment and guideline instructions
- Tested OD/TCC Solenoid
- Custom laser cut separator plates
- Castings flat sanded
- Castings cleaned in ultrasonic cleaner
- All threads checked and repaired if needed
- Bores vacuum checked and repaired for excessive wear
- Static line pressure set to 150PSI and 190PSI in 4TH/TCC Lockup. Valve body does not require any external line pressure adjustment.